01 Heat Recovery Ventilation (HRV)
02 Sustainable heating systems
03 Sustainable cooling systems


01 Heat Recovery Ventilation (HRV)
index
double flow ventilation

Common to install when:
- Extreme climate zones (arctic, cool, very warm)
- Noise pollution areas
- Air pollution areas
- Allergic people


System choose criteria


source:ClenFilter

minimum F7 for fresh outdoor air inlet
minimum G4 for exhaust air from local


hygiene


confort


0 °C = 273,15 K

Source: Gjennestad, Magnus & Aursand, Eskil & Magnanelli, Elisa & Pharoah, J.G.. (2018). Second-law energy efficiency as performance indicator for heat and energy recovery ventilators.

Requirements
- Min. Outdoor temperature 16,5ºC a -10ºC
- Simultaneity (30%-70%-100%-130%)
- Noise control. Max. 35 dB(A) inhabited rooms



efficiency


- efficiency coefficient, η≥75%
- energy demand≤0,45 Wh/m3
- energy saving mode max. 1W
- airtight and insulation
- air balance between fresh outdoor air and exhaust air



frost protection


membrane HRV


what if HRV is insufficient?
we need to install supplementary heating and/or cooling systems

02 Sustainable heating systems
03 Sustainable cooling systems
cooling demand< 150 Wh/m2d

cooling demand < 250 Wh/m2d -> aerothermal, geothermal

cooling demand > 250 Wh/m2d -> chilled ceiling/beams, cooling towers

depends of the demand, and combine it with passive strategies (shading, solar protections)

do you already know any of them?
Comparison of delivered energy in conventional house and in house built to Passivhaus Standard.
Source: Passivhaus Institut. http://www.passiv.de.
Source: Building Energy Exchange
traditional heat pump
aerothermal heat pump
geothermal heat pump
biomass
also provides cooling
ventilation is enough

traditional air conditioned machines contain high pollutant refrigerant


Always try to find refrigerants with lower Global Warming Potential (GWP)


GWP is a relative way to measure the amount of greenhouse gases that traps in the atmosphere
,,


,,


gas radiator (uncertain prices in the future)
cooling tower